Time: 2023-01-09
High reliability, high performance
Convert multipath analog signals & digital signals to CAN signal
Support CANOpen protocol
Center position、Keeping area、Output slope can be setting
Small size, high density of I/O terminal
Cost-effective item
Operating temperature range
-25℃~+85℃
Storage temperature range
-25℃~+105℃
Applied voltage
8~32V
Input signal
6 path analog signals; 10 path switch signals
Lower limit of input analog
100mV
Upper limit of input analog
4.95V
Analog conversion accuracy
0.5%
Switching level rule
TTL
Max. input signal resolution
4096(12bit)
Communication interface
1 CANbus
Communication protocol
Standard CANopen